JULABO Refrigerated and Heating Circulators are suitable for temperature application to external systems with simultaneous operation in the bath tank. The units provide high heating/cooling capacities to ensure rapid heat-up and cool-down times. With Active Cooling Control to +200°C (not on ED models), FP models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Convenient cleaning of dust by removable venting grid. Some models have a handle or castors to allow easy transport. All models provide a drain port on the front for conveniently draining the bath fluid. Typical applications: Temperature applications to external, closed systems, such as for example photometers, refractometers, viscometers, etc. For simultaneous application to small objects in the circulator bath.
• VFD COMFORT DISPLAY
• Keypad for setpoints, warning/safety values and menu functions
• PID3 cascade temperature control
• ATC3 3-Point-Calibration
• Pt100 External sensor connection for measurement and control
• SMART PUMP, electronically adjustable pump stages
• Early warning system for low liquid level (DBGM 203 06 059.8)
• Adjustable high temperature cut-out, visible via display
• RS232 interface for online communication
• Integrated programmer for 10 program steps
• Active Cooling Control
Image(s) are representative of the product group and not necessarily the individual product.
Model: F25-ME
Capacity (L): 4.5
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -28 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 1
Cooling Capacity: 0.35 kW @ 20 DEG C 0.25 kW @ 0 DEG C 0.06 kW @ -20 DEG C
Bath Opening W x L x D (in.): 4.7 x 5.5 x 5.5
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 9.1 x 16.5 x 24
Model: F26-ME
Capacity (L): 4.5
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -28 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 1
Cooling Capacity: 0.26 kW @ 20 DEG C 0.2 kW @ 0 DEG C 0.06 kW @ -20 DEG C
Bath Opening W x L x D (in.): 4.7 x 5.5 x 5.5
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 16.5 x 16.5 x 16.5
Model: F32-ME
Capacity (L): 8
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -35 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 1
Cooling Capacity: 0.45 kW @ 20 DEG C 0.39 kW @ 0 DEG C 0.15 kW @ -20 DEG C
Bath Opening W x L x D (in.): 7.1 x 4.7 x 5.9
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 12.2 x 16.5 x 25.2
Model: F33-ME
Capacity (L): 16
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -30 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 1
Cooling Capacity: 0.5 kW @ 20 DEG C 0.39 kW @ 0 DEG C 0.15 kW @ -20 DEG C
Bath Opening W x L x D (in.): 9.1 x 5.5 x 7.9
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 14.2 x 18.1 x 27.2
Model: F34-ME
Capacity (L): 20
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -30 to +150
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 1
Cooling Capacity: 0.45 kW @ 20 DEG C 0.32 kW @ 0 DEG C 0.14 kW @ -20 DEG C
Bath Opening W x L x D (in.): 9.4 x 11.8 x 5.9
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 15 x 22.8 x 24.4
Model: FP40-ME
Capacity (L): 16
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -40 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 2
Cooling Capacity: 0.68 kW @ 20 DEG C 0.5 kW @ 0 DEG C 0.32 kW @ -20 DEG C 0.04 kW @ -40 DEG C
Bath Opening W x L x D (in.): 9.1 x 5.5 x 7.9
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 14.6 x 18.1 x27.7
Model: FP50-ME
Capacity (L): 8
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -50 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 2
Cooling Capacity: 0.9 kW @ 20 DEG C 0.8 kW @ 0 DEG C 0.5 kW @ -20 DEG C 0.16 kW @ -40 DEG C
Bath Opening W x L x D (in.): 7.1 x 4.7 x 5.9
Cooling of Compressor: Air
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 16.5 x 19.3 x 27.6
Model: FPW50-ME
Capacity (L): 8
Flow Rate (L/min.): 11 to 16
Working Temperature Range ( DEG C): -50 to +200
Temperature Stability ( DEG C): +/-0.01
Temperature Display: VFD
Heating Capacity (kW): 2
Cooling Capacity: 0.9 kW @ 20 DEG C 0.8 kW @ 0 DEG C 0.5 kW @ -20 DEG C 0.16 kW @ -40 DEG C
Bath Opening W x L x D (in.): 7.1 x 4.7 x 5.9
Cooling of Compressor: Water
Barbed Fittings Diameter (I.D. / mm): 8 / 10
Dimensions W x L x H (in.): 16.5 x 19.3 x 27.6