H-B Double
- SKU:
- 354-30010
Description
These environmentally safe thermometers are PFA safety coated to keep liquid and glass contained in the event of breakage.
• Non-toxic, biodegradable, Enviro-Safe liquid, against lead-free, yellow back glass provides easy readability and fewer reading errors.
• Ideal for use in chemical/petrochemical laboratories, universities, scientific institutions, food and beverage processing, pharmaceutical and medical industries, dairies, breweries and distilleries
• Manufactured and tested by Sciencewares USA quality team
• Traceable to NIST
• Includes a multi-language (English, French, German, Italian, Portuguese, and Spanish) Statement of Accuracy and Traceability
Image(s) are representative of the product group and not necessarily the individual product.
Total Immersion
Range: 0 to 230 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F
Length mm (in.): 300 (12)
Total Immersion
Range: 0 to 300 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F, +/-3 DEG F above 212 DEG F
Length mm (in.): 300 (12)
Total Immersion
Range: -10 to 110 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C
Length mm (in.): 200 (7.9)
Total Immersion
Range: -10 to 150 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C, +/-1.5 DEG C above 100 DEG C
Length mm (in.): 200 (7.9)
Total Immersion
Range: -10 to 225 DEG C
Divisions: 1 DEG C
Accuracy: 1.5 DEG C, +/-2 DEG C above 100 DEG C, +/-2.5 DEG C above 200 DEG C, +/-3 DEG C above 230 DEG C
Length mm (in.): 350 (14)
Total Immersion
Range: -20 to 110 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C
Length mm (in.): 300 (12)
Total Immersion
Range: -20 to 150 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG Cm +/-1.5 DEG C above 100 DEG C
Length mm (in.): 300 (12)
Total Immersion
Range: 20 to 230 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F
Length mm (in.): 200 (7.9)
Total Immersion
Range: 20 to 30 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F, +/-3 DEG F above 212 DEG F
Length mm (in.): 200 (7.9)
Total Immersion
Range: 20 to 440 DEG F
Divisions: 2 DEG F
Accuracy: +/-3 DEG Fm +/-4 DEG F above 230 DEG F, +/-5 DEG F above 392 DEG F
Length mm (in.): 350 (14)
Partial Immersion: 50 mm (2 in.)
Range: -10 to 110 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C
Length mm (in.): 200 (7.9)
Partial Immersion: 50 mm (2 in.)
Range: -10 to 150 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C, +/-1.5 DEG C above 100 DEG C
Length mm (in.): 200 (7.9)
Partial Immersion: 50 mm (2 in.)
Range: 20 to 230 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F
Length mm (in.): 200 (7.9
Partial Immersion: 50 mm (2 in.)
Range: 20 to 300 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F, +/-3 DEG F above 212 DEG F
Length mm (in.): 200 (7.9)
Partial Immersion: 76 mm (3 in.)
Range: -10 to 260 DEG C
Divisions: 1 DEG C
Accuracy: +/-1.5 DEG C, +/-12 DEG C above 100 DEG C, +/-2.5C above 200 DEG C, +/-3 DEG C above 230 DEG C
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: -10 to 70 DEG C
Divisions: 0.5 DEG C
Accuracy: +/-0.5 DEG C
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: -20 to 150 DEG C
Divisions: 1 DEG C
Accuracy: +/-1 DEG C, 1.5 DEG C above 100 DEG C
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: -30 to 120 DEG F
Divisions: 1 DEG F
Accuracy: 1 DEG F
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: 0 to 230 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: 0 to 300 DEG F
Divisions: 2 DEG F
Accuracy: +/-2 DEG F, +/-3 DEG F above 212 DEG F
Length mm (in.): 300 (12)
Partial Immersion: 76 mm (3 in.)
Range: 20 to 500 DEG F
Divisions: 2 DEG F
Accuracy: +/-3 DEG F, +/-4 DEG F above 230 DEG F, +/-5 DEG F above 392 DEG F
Length mm (in.): 350 (14)