Thermo Scientific™ Barnstead™ GenPure™ xCAD Plus Ultrapure Water Purification System

Contact: AdvanceEmail@protonmail.com

SKU:
887-10253
$9,969.45

Description

Gain flexibility in the lab with the Thermo Scientific Barnstead GenPure xCAD (Extended Control and Dispenser) Plus water system. Its advanced technologies allow for simultaneous dispensing from up to three remote dispensers. This lab water system comes with leak detection, electronic dispensing for fully automatic volume control, and feed water monitoring that alerts users to fluctuations in the feed water quality. All consumables needed for start-up come with the system, including feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, and sterile filter.

• Ergonomic dispensing arm provides precise volume dosing at the press of a button
• One-of-a-kind design provides access to all system controls at your fingertips
• Additional measuring cell monitors feed water conductivity
• A fault message will be displayed if the quality of the feed water drops below the set value
• An error message is displayed when internal leaks are detected
• Aquastop quick-connect capability enables cartridge replacement within seconds
• Electronic dosing yields fully automatic volume control of 0.01 to 65 L with < 2% accuracy
• Conductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01 cm-1
• Temperature measurements are made by a platinum chip sensor with +/-0.1°C accuracy
• Real-time clock and code-protected operating system prevents unauthorized changes to system settings
• RS-232 interface with adjustable send-interval offers safe data transfer of all measured data, faults, date, and time
• Digital microprocessor control automatically monitors and stores faults from the last four weeks
• USP-compliant conductivity measurement with temperature compensation can be switched on or off
UV Photo-oxidation 185/254 nm:
• High performance UV assembly reliably reduces the content of microorganisms and their metabolites
• UV oxidation also reduces organic compounds in the water to ultra-low levels
Online TOC measurement with UV intensity monitoring (available on systems with TOC option only):
• Real-time TOC monitoring offers continual measurement of organic substances present in the water
• Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity
• Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements

Specifications:
• Flow rate: up to 2 L/min.
• Operating pressure min./max.: 29 to 87 psi (2 to 6 bar)
• Electrical requirements: 90 to 240V, 50/60 Hz
• Power consumption: 0.1 kW
• Feed water connector: 3/4 in. NPT
• Dimensions (W x D x H): 14.6 x 13 x 24 in.
Image(s) are representative of the product group and not necessarily the individual product.

Applications: Biosciences (cell and tissue culture media, PCR, DNA, monoclonal antibodies)
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): <0.003
DNase (pg/µL): <0.4
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): <0.001
TOC Monitor: Standard
Flow Rate (L/min.): Up to 2

Applications: Biosciences (cell and tissue culture media, PCR, DNA, monoclonal antibodies
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): <0.003
DNase (pg/µL): <0.4
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): <0.001
TOC Monitor: Standard
Flow Rate (L/min.): Up to 2

Applications: Chemical analysis (trace analysis, HPLC, IC, ICP-MS, TOC measurements)
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): n/a
DNase (pg/µL): n/a
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): n/a
TOC Monitor: Standard
Flow Rate (L/min.): Up to 2

Applications: Inorganic and organic trace analysis, HPLC, ICP-MS, IC, TOC analysis
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): n/a
DNase (pg/µL): n/a
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): n/a
TOC Monitor: n/a
Flow Rate (L/min.): Up to 2

Applications: Molecular biology, PCR, DNA, monoclonal antibodies, cell culture media
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): <0.003
DNase (pg/µL): <0.4
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): <0.001
TOC Monitor: n/a
Flow Rate (L/min.): Up to 2

Applications: Molecular biology, PCR, DNA, monoclonal antibodies
Resistance at 25°C (M.cm): 18.2
Conductivity (µS/cm): 0.055
TOC (ppb): 1 to 5
RNase (ng/mL): <0.003
DNase (pg/µL): <0.4
Bacteria (CFU/mL): <1
Particles (0.22 µm/mL): <1
Endotoxins (EU/mL): <0.001
TOC Monitor: n/a
Flow Rate (L/min.): Up to 2

View AllClose