Wheaton* Acura* Manual 815 Fixed Volume Pipettes

Contact: AdvanceEmail@protonmail.com

SKU:
969-59367
$256.60

Description

Fixed volume micropipettes show the most stable performance. They provide consistent results for any analytical or routine diagnostic tests by eliminating the risk of erroneous volume setting.

• Slim ergonomic design and lightweight
• Soft plunger activation
• Justip™ adjustable tip ejector fitting most tips
• User calibration with integrated key
• Color coded smartie cap
• Selection includes macropipette volumes
Image(s) are representative of the product group and not necessarily the individual product.

Volume (µL): 1000
Inaccuracy (E%): < +/- 0.6%
Imprecision (CV%): < 0.2%
Use Tip Size (µL): 1000

Volume (µL): 100
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 200

Volume (µL): 10
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.7%

Volume (µL): 120
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.4%
Use Tip Size (µL): 200

Volume (µL): 150
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 200

Volume (µL): 15
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.5%
Use Tip Size (µL): 200

Volume (µL): 1
Inaccuracy (E%): < +/- 2.0%
Imprecision (CV%): < 2.0%
Use Tip Size (µL): 10

Volume (µL): 200
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.4%
Use Tip Size (µL): 200

Volume (µL): 20
Inaccuracy (E%): < +/- 0.75%
Imprecision (CV%): < 0.5%
Use Tip Size (µL): 200

Volume (µL): 250
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.4%
Use Tip Size (µL): 1000

Volume (µL): 25
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.6%
Use Tip Size (µL): 200

Volume (µL): 300
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.4%
Use Tip Size (µL): 1000

Volume (µL): 30
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.6%
Use Tip Size (µL): 200

Volume (µL): 400
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 1000

Volume (µL): 40
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.5%
Use Tip Size (µL): 200

Volume (µL): 500
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 1000

Volume (µL): 50
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.5%
Use Tip Size (µL): 200

Volume (µL): 5
Inaccuracy (E%): < +/- 1.4%
Imprecision (CV%): < 1.0%
Use Tip Size (µL): 10

Volume (µL): 600
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 1000

Volume (µL): 60
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.6%
Use Tip Size (µL): 200

Volume (µL): 700
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.2%
Use Tip Size (µL): 1000

Volume (µL): 70
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.6%
Use Tip Size (µL): 200

Volume (µL): 750
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.2%
Use Tip Size (µL): 1000

Volume (µL): 75
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.5%
Use Tip Size (µL): 200

Volume (µL): 800
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.2%
Use Tip Size (µL): 1000

Volume (µL): 80
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.4%
Use Tip Size (µL): 200

Volume (µL): 900
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.2%
Use Tip Size (µL): 1000

Volume (µL): 90
Inaccuracy (E%): < +/- 0.7%
Imprecision (CV%): < 0.3%
Use Tip Size (µL): 200

View AllClose